TELEPHONE AND ALARM CABLES
TPVF F2 TWISTED PAIR INDIVIDUALLY SHIELDED
shielded telephone cables, for fixed indoor installations
APPLICATION
Telephone cable for indoor installation, insulated with a special flame retardant PVC compound or low toxic smoke Halogen-free material in accordance with EN-IEC flame and smoke standards.
SPECIAL FEATURES
TPVF F2 PVC:
IEC 60332-1-2 : Flame retardant
IEC 60332-3-24 : Circuit integrity
EN 50575 : 2014 + A1 : 2016
IEC 60332-1-2 : Flame retardant
IEC 60332-3-24 : Circuit integrity
EN 50575 : 2014 + A1 : 2016
TPGF LSZH::
IEC 60332-1-2 : Flame retardant
IEC 60332-3-24 : Circuit integrity
EN 50267-2-3: Acidity of gases
EN 61034-2: Smoke density
EN 50575 : 2014 + A1 : 2016
REMARKS
Conform to RoHS directive
Conform to Low-Voltage Directive (LDV) 2014/35/EU
Conform to Low-Voltage Directive (LDV) 2014/35/EU
TECHNICAL FEATURES
Operating temperature
-5°C ÷ +70°C
Rated voltage
150V
Test voltage
1000V
Conductor class
CuSn Class 1 DIN VDE 0812 /IEC 60228
Insulation
PVC (Quality TI2)
Core identification
CEI 46-5
Assembly /Drain Wire
Pairs twisted together with CuSn solid drain wire
Individual shield
Pair shielded with alum./polyester tape reversed
Sheath material
PVC (Quality TM2) White RAL 9003
Min. Bending radius
Fixed installation 7,5 x cable Ø
Other versions
TPGF (LSZH) Low smoke zero halogen
CPR (DoP) – EU 305/11
TPVF F2 PVC
SYSTEM AVCP 1+
Cca
DOWNLOAD
SYSTEM 3
Dca
DOWNLOAD
SYSTEM 3
Eca
DOWNLOAD
SYSTEM 4
Fca
DOWNLOAD
TPGF LSZH
SYSTEM AVCP 1+
B2ca
DOWNLOAD
SYSTEM AVCP 1+
Cca
DOWNLOAD
SYSTEM 3
Dca
DOWNLOAD
SYSTEM 3
Eca
DOWNLOAD
SYSTEM 4
Fca
DOWNLOAD